23 Feb The Main Duties of a Cutout

Posted at 14:10h in Cutouts 0 Comments
2 Likes

The Three Important Duties of a Fused Cutout By Michael Murphy If you look up at the electrical distribution lines overhead, you are likely to see a fused cutout.  That little device...

Read More

22 Feb Why Strike Distance Is Important for Insulators

Posted at 21:30h in Insulators 0 Comments
2 Likes

Why is Strike Distance So Important in Insulator Design? By Jon Rennie When designing and specifying an insulator, one of the key electrical characteristics is its strike distance. So what is strike...

Read More

22 Feb What is meant by Creep Distance in Insulator Design?

Posted at 21:18h in Insulators 0 Comments
2 Likes

What is meant by Creep Distance in Insulator Design? By Jon Rennie You might have heard the term creepage or creep distance when referring to insulator design and specifications. So what is...

Read More

22 Feb The Super Powers of Insulators

Posted at 21:13h in Insulators 0 Comments
0 Likes

The Super Powers of Insulators By Jon Rennie Insulators are everywhere. They are one of the most common components used in electrical transmission and distribution applications yet they are still somewhat misunderstood....

Read More
Peak Demand Alta Series Current Transformers

21 Feb Can a high accuracy CT really gain more revenue?

Posted at 19:53h in Instrument Transformers 0 Comments
0 Likes

Can a high accuracy current transformer really gain more revenue? By Steve Lindsay In short, Yes!  A current transformer (CT) with higher accuracy will typically generate more revenue for a utility than...

Read More

21 Feb The Dielectric Strength of Insulating Materials

Posted at 19:42h in Insulators 0 Comments
1 Like

The Dielectric Strength of Insulating Materials Electrical insulators are used throughout transmission and distribution circuits to separate voltage from ground. The materials used in the design and production of electrical insulators...

Read More

17 Feb Creep Distance and Contamination Levels

Posted at 22:06h in Insulators 0 Comments
0 Likes

Different contamination levels require special consideration when designing or specifying electrical distribution equipment.  This is critical to ensure products will perform safely over time.  Specifying engineers need to define not...

Read More

23 Jan Advantages of ISO Standards

Posted at 14:23h in Cutouts 0 Comments
1 Like

Advantages of ISO Standards By: Jessica Seelman   Initially one may think an ISO Standard requires too much time, money, and resources but ISO Standards can be very beneficial to any size business. ...

Read More

23 Jan The Importance of Annealing CT Cores

Posted at 14:22h in Instrument Transformers 0 Comments
0 Likes

Why do you need to anneal the electrical steel core in a current transformer? By: Jessica Seelman The annealing process of a current transformer (CT) core is a critical operation within the...

Read More
  • 1
  • 2
  • 3
Reach Us
Peak Demand Inc.
605 Tarboro Street Annex SW
Wilson, NC 27893
Toll Free: 1.844.PEAK.247
Local: 252.360.2777
Fax: 252.375.3311
info@peakdemand.com
Quick Links
MyPeakDemand.com
Sales Partners
Contact Us
News and Events
Careers
Terms of Use
Privacy Policy
Trademark Policy
Search
     © Peak Demand Inc. All Rights Reserved.